+8
−3
+2
−0
Loading
The following patches will aggregate multiple Data-OUT PDUs into a single SCSI write up to 64KB. Any variable to accumulate data length is necessary. Hence add data_len to mobj and accumulate read data length into mobj->data_len, and then refer mobj instead of pdu->data and pdu->data_segment_len to submit write subtask. Signed-off-by:Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com> Change-Id: I6354534769e67c0fd995bbc3c2b4a80d21a23915 Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6422 Tested-by:
SPDK CI Jenkins <sys_sgci@intel.com> Community-CI: Mellanox Build Bot Reviewed-by:
Changpeng Liu <changpeng.liu@intel.com> Reviewed-by:
Ziye Yang <ziye.yang@intel.com> Reviewed-by:
Jim Harris <james.r.harris@intel.com>